Viledon Filtermatten

Viledon Accessories

Mounting frames for air filters:

  • Application: Construction and rebuilding of air handling systems with any desired dimensions.
  • Use: Secure holding of Viledon pocket filters and cassette filters (MaxiPleat, NanoPleat, CarboPleat, DuoPleat).
  • Construction: Stainless high-grade steel (Material 1.4301) or galvanised steel sheet (U-St 1203), burr-free, inherently rigid, in 4 sizes, positive clamp spring system with mechanical locking
  • A silicone-free plug-on gasket with metal insert and hollow compartment is supplied with each mounting frame.
Type Length / mm Width / mm Depth / mm No. of
clamps
ARV NF 1/1 610 610 75 4
ARE NF 1/1
ARV NF 5/6 508 610 75 4
ARE NF 5/6
ARV NF 1/2 305 610 75 4
ARE NF 1/2
ARV NF 1/4 305 305 75 4
ARE NF 1/4
Special variants in aluminium and other high-grade steel versions are available upon request.

Viledon plug-on gasket for mounting frames:

  • Made of a U-shaped metal carrier profile and a closed-pore rubber jacketing with integral sealing lips and hollow compartment
  • Can be fitted without tools simply by pressing the gasket by hand onto the metal edge
  • The gasket is kept in place by the clamping effect of the rubber lips, adhesive or special fixing agents are not required
  • The Viledon plug-on gasket is weatherproof and thermally stable within a range from approx. -40°C to +100°C, and also extremely long-lasting
  • Highly flexible - silicone-free
  • Test certificate on paint compatibility from an independent test institute (Fraunhofer Institute, Stuttgart)
  • Color of the gasket: black

Installation instruction for the plug-on gasket

  • Begin assembly in the middle of one side - not in a corner!
  • Fit the gasket onto the mounting frame with the hollow compartment facing inwards.
  • Form the corners completely, without overstretching the gasket.
  • Continue fitting the gasket until you reach the starting point.
  • Check the correct position of the gasket before cutting to length.
  • Cut the gasket to length with a right-angled cut, leaving an overlength of approx. 5 mm, and join the two ends together.

Differential pressure measurement equipment:

Differential pressure gauge TMP 2-5000 Anzeigegerät TMP 2-5000 Display precision: 5% at 20°C
Temperature range -7°C up to +60°C
Display range: 0 - 500 Pa
  0 - 1000 Pa
Application: Low precision measurements
     
Differential pressure switch TM 190 Schaltgerät TM 190 Switch precision: 3% at 20°C
Temperature range: -4°C up to +85°C
Protection: IP 65
Range: 35 - 1250 Pa
Comment: No display, only switching capability
Application: Alert signal function for operation of fans, engines - also useable as emergency-off switch.
     
Differential pressure gauge TMP 2000 Anzeigegerät TMP 2000 Display precision: 2% up to 20°C
Temperature range: -54°C up to +60°C
Display range: 60 Pa - 30 kPa
Application: Measurement of differential pressure
     
Differential pressure gauge TM 200 Anzeigegerät TM 200 Display precision: 2% up to 20°C
Temperature range: -54°C up to +60°C
Protection: IP 54
Display range: 60 Pa - 30 kPa
Application: Measurement of differential pressure
     
Differential pressure switch TM 192 Schaltgerät TM 192 Display precision: 2% up to 20°C
Switch precision: 3% at 20°C
Temperature range: -54°C bis +60°C
Protection: IP 54 (IP 65
Display range: 0 - 500 Pa 0-1000 Pa
Comment: Display and switching device with 2 electrical and 1 pressure sensor(s); for 1 or 2 switchpoints
Application: Observation of differential pressure; On, Off and alert signal function